- Frequency inverter
- general purpose frequency inverter low voltage 690V and lower
- special purpose frequency inverter low voltage 690V and lower
- four quadrants frequency inverter low voltage
- Servo drives low voltage
- medium voltage (1140V)
- high voltage (3.3KV/6.6KV/10KV)
- Accessories
- Option cards
- Solution
Address: No.4 Building, Gaofa Industrial Park, Longjing, Nanshan District, Shenzhen, 518055, China
ZipCode: 518055
Tel: +86-755-86312856 86318602 86318456 (direct line) Mobile: +86 133 169 613 20 /+86 135 100 656 90
Fax: +86-755-8602 8412
Email: wangjian@invt.com.cn
Total 45 Product(s)
-
-
1.vfd, CHE100 series sensorless vector control frequency inverter
1phase 220V/230V±15% 0.4kW~2.2kW 3phase 220V/230V±15% 0.75kW~55kW 3phase 380V/415V/440V/460V/480V/525V±15% 0.75kW~2MW ◆Sensorless Vector Control (SVC), V/F Control. ◆Achieve excellent sensor...
-
-
2.frequency inverter, CHE100 series mini vector control frequency inverter (0.4/0.75KW)
1phase 220V/230V±15% 0.4kW~0.75kW Output frequency: 0.00 ~ 400.00Hz Efficiency: >98% (at rated power) Control mode: Sensorless vector control (SVC), V/F control Overload capacity: 150% rated current for 60 s Speed accuracy: ±0.5% max. speed (SVC) Speed adjusting range: 1:100 Multi-steps speed control: 8 steps Autotuning function: ...
-
-
3.ac drives, CHV100 series close loop vector control frequency inverter
3 phase 220V/230V±15% 1.5kW~45kW 3 phase 380V/415V/440V/460V/480V/525±15% 1.5kW~2MW 3 phase 660V/690V±15% 11kW~2.8MW ◆ Control Mode Sensorless vector control (SVC), Vector control with PG (VC), V/F control. ◆ Dual-CPU control platform:16bit DSP is responsible for current vector arithmetic while 32 bit ARM is in charge of control fun...
-
-
4.vfd, CHF100 series high performance universal frequency inverter
1 phase 220V/230V±15% 0.75kW~2.2kW 3 phase 220V/230V±15% 0.75kW~55kMW 3 phase 380V/415V/440V/460V/480V/525V±15% 1.5kW~2MW Input Frequency Range: 47~63Hz Output Voltage Range: 0~rated input voltage Output Frequency Range: 0~400Hz Control Mode: V/F control. Overload Capacity: 60s with 150% of rated current, 1...
-
-
5.variable speed drives, CHV110 series energy saving cabinet (frequency inverter)
3phase 220V/230V±15% 7.5kW~75kW 3phase 380V/415V/440V±15% 7.5kW~75kW Sensorless Vector Control (SVC), V/F Control Frequency source:compare pressure and flow signals output. Fast current limiting function, with an instantaneous impulse current as high as 300% overload capability up to 180%/30 seconds; Automatic reset and power...
-
-
6.speed control, CHV130 series special frequency inverter for wiring-drawing application
3 phase 380V/415V/440V/460V/480V/525V±15% 2.2kW~560kW high performance vector control. Simatic platform Built in multifunction to simplify system, reduce cost, and improve reliability Multi levels speed synchronous function Speed difference or pressure sensor feedback synchronous rolling winding control Free PID function for const...
-
-
7.ac drives, CHV150 Series high speed frequency inverter
3 phase 380V/415V/440V/460V/480V/525V±15% 1.5kW~22kW Output frequency: 0.00 ~ 3000.00Hz Efficiency: >98% (at rated power) Control mode: Vector control with PG (VC), sensorless vector control (SVC), V/F control Overload capacity: 150% rated current for 60 s (SVC), 180% rated current for 10 s (VC) Speed accuracy: 0.5% of max speed (SVC), 0...
-
-
8.variable speed drives, CHV160 series special frequency inverter for multi-pumps water supply application
3 phase 220/230V/380V/415V/440V/460V/480V/525V±15% 5.5kW~630kW Control mode: V/F control Overload capacity: 120% rated current for 60 s Speed accuracy: ±0.5% max. speed (SVC) Speed adjusting range: 1:100 Multi-steps speed control: 16 steps Built-in DC reactor from 18.5KW to 90KW to improve power factor Timing control: Set ei...
-
-
9.vfd, CHV170 series special frequency inverter for tension control application
3 phase 380V/415V/440V/460V/480V/525V±15% 2.2kW~560kW Sensorless torque control mode combine with precise rolling diameter and auto torque compensation algorithm. Built-in speed+torque control mode to reduce tension fluctuation. Simatic platform Built in multifunction to simplify system, reduce cost, and improve reliability Multi l...
-
-
10.speed control, CHV180 series special frequency inverter for elevator applicatio
3 phase 380V/415V/440V/460V/480V/525V±15% 4kW~30kW control structure:DSP _32bit MCU. Maximum speed reach to 4m/s Two types speed control mode:Multi-speed and analog speed control Special function for maintenance External EPS ensure elevator emergency running Three forced deceleration for UP and Down to prevent crashing to bo...
-
-
11.inverter, CHV190 series frequency inverter/drive Special for crane
3 phase 380V/415V/440V/460V/480V/525V±15% 4kW~560kW Internal contracting brake control and monitor function. Separated power supply control for control circuit and power circuit. better for faulty detection and maintenance; Speed increasing function for light load or without load can realize faster speed for sky-hook to improve the effi...
-
-
12.frequency inverter, CHA100 series frequency inverter/drive Four quadrants inverter
3 phase 380V/415V/440V/460V/480V/525V 132kW~1200kW Less current harmonics in the Grid side. Base waveform power factor is close to 1(full load) Excellent close loop vector control, Zero speed 200% Mn.. Three kinds control mode: sensorless vector control, vector control with PG, V/F control. The same structure of r...
-
-
13.servo drives, CHS100 series Servo inverter/drive
1 phase 220V±15% 0.75kW~1.5kW 3 phase 220V±15% 0.75kW~1.5kW Control methods: Sine waveform PWM Control with vector control. 32bit DSP+FPGA Parameter setting mode: Manual control parameter setting, also can set by the communication with PC, has anti-vibration and filter functions. Control mode: Position mode, speed ...
-
-
14.ac drives, CHV series medium voltage (1140V) high performance frequency inverter
3 phase 1140V±15% 45kW~2.8MW Output frequency: 0.00 ~ 400.00Hz Efficiency: >98% (at rated power) Control mode: Sensorless vector control (SVC), V/F control Overload capacity: 150% rated current for 60 s Speed accuracy: ±0.5% max. speed (SVC) Speed adjusting range: 1:100 Multi-steps speed control: 16 steps ...
-
-
15.vfd, CHH series high voltage (3.3/6.6/10KV) frequency inverter
3 phase 3.3KV/6.6KV/10kV 315kW~7100kW High integrated techology and completely digital control system, good anti interference ability. Control system power supply redundant design. Multi monitor for power units Power unit bypass function to achieve power unit redundant design. Standard RS485terminal to communicate with DCS. More...
-
-
16.inverter, dynamic braking unit
220V/380V/660V/1140V 55kW~315KW High braking capability:Brake continuously for full load when braking rate is 50%: Barke for five minutes for full load when braking rate is 100% Wide voltage range : offer six braking threshold voltage Comprehensive protection function: prevent inverter from short circuit of braking resistor
-
-
17.variable speed drives, regenerative braking unit frequency inverter
380V/660V 7.5kW~250kW Adopt IGBT as regenerative module ensure low harmonics to the mains(THD is less than 4% compared with traditional rectifier unit High braking capability:200% overload Wide voltage range:300~460/530~790V,braking threshold voltage is adjustable. Model No. Input voltage Rated Power (KW) DC rated current ...
-
-
18.vfd, emc filter for frequency inverter
Suitable for drives from 0.75KW~630KW. EMC filter is used to minimize interference and radio noise in order to meet EMC compliance.
-
-
19.vfd, ac input reactor for ac drives
Suitable for drives from 0.75KW~630KW. In order to prevent the rectifier damage result from the large current, AC reactor should be installed at the input side. It can also prevent rectifier from sudden variation of power voltage or harmonic generated by phase-control load.
-
-
20.vfd, ac output reactor
Suitable for drives from 0.75kW~630KW. When the distance between inverter and motor is more than 50m, inverter may be tripped by over-current protection frequently because of the large leakage current resulted from the parasitic capacitance with ground. And the same time to avoid the damage of motor insulation, the output reactor should be install...




Select
to 

View list
items per page